Fujitsu M10-4S Server User Manual


 
Note -
See the procedure for system-stopped maintenance for inactive/cold maintenance in a
single-chassis configuration.
Caution -
To completely shut down the system, all the power cords must be
removed. If the power cords are not removed, an electrical failure may occur.
Note -
Use the DR of the system board on a physical partition for active/cold maintenance.
For the XCP and Oracle VM Server for SPARC/SRU versions that correspond to the DR, see
the latest Product Notes.
Note -
Active/cold maintenance can be performed only for a building block configuration.
XSCF>
showlogs error
8.3.5 Precautions for removal
Note the following points when removing memory:
Observe the memory installation rules when you remove memory. For details, see
"8.2.1 Memory mounting rules."
8.4 Enabling the Removal of Memory
This section describes the preparations that must be completed prior to the removal
of memory. The preparation procedure differs depending on the maintenance type as
follows:
Active/Cold maintenance
Inactive/Cold maintenance
System-stopped maintenance
8.4.1 Active/Cold maintenance
1.
Open the r ack do or.
2.
Log in to the XSCF s hell.
3.
Execute the sho w log s command to identify th e component requiring
maintenance.
For details, see "3.3.5 Checking log information."
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual