Fujitsu M10-4S Server User Manual


 
Table 3-3
Predictive self-repairing messages (continued)
Output Displayed Description
Nov 1 16
30
20 dt88-292 REC-ACTION
Schedule a repair procedure to replace the affected
device.Use Nov 1 16
30
20 dt88-292 fmdump -v –u
EVENT_ID to identify the device or contact Sun for
support.
REC-ACTION: Brief description of
the corrective action the system
administrator should apply
XSCF>
setlocator -b 1 blink
3.3.7 Identifying the location of the chassis requiring
maintenance
Execute the setlocator command to identify the location of the chassis requiring
maintenance by causing the CHECK LED on the operation panel and the CHECK
LED (locator) on the rear panel to blink.
1.
Log in to the XSCF s hell.
2.
Execute the setlocator command t o blink th e CHECK L E D of the chassis
requiring mai nten ance, and d etermine its location.
The CHECK LEDs on the operation and rear panels blink.
An execution example in which the chassis requiring maintenance is the master
chassis is shown below. When specifying a different chassis such as BB#01, set
"setlocator -b 1 blink."
For details on where to find and how to check the CHECK LEDs, see "2.3
Checking the LED Indications."
3.4 Downloading Error Log Information
This section describes the operation for downloading error log information.
To download error log information, use the XSCF log fetch function. The XSCF unit
has a maintenance USB port so that maintenance information such as error logs can
be obtained easily.
For details, see "12.1.15 Saving a log to a file with snapshot" and "12.1.16 Saving a
log to a local USB device" in the Fujitsu M10/SPARC M10 Systems System Operation
and Administration Guide.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual