Fujitsu M10-4S Server User Manual


 
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
2.
Return to the operation of the XSCF firmw are replacefru co mman d to confirm
that th e chassis has been incorpor ated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
3.
Power on th e physical p artition r equ iring maintenanc e.
For details, see "6.3 Powering On the Physical Partition Requiring Maintenance."
4.
Close t h e rack d oor.
10.6.5 System-stopped maintenance
1.
Connect all the po wer c ords to the PSU backplane unit.
For details, see "6.5.1 Installing the power cord."
2.
Return to the operation of the XSCF firmw are replacefru co mman d to confirm
that th e chassis has been incorpor ated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
For a single-chassis configuration, you do not have to incorporate the chassis.
Proceed to step 3.
3.
Start the entire system.
For details, see "6.4 Starting the Entire System."
4.
Close t h e rack d oor.
Chapter 10 Maintaining the Power Supply Units 203