Fujitsu M10-4S Server User Manual


 
Table 28-1
Types of maintenance for cable kit
Configuration Active/hot Active/cold Inactive/hot I n a ctive/cold System stopped
Building block configuration
Unsupported Unsupported
(*1)
Unsupported Unsupported
(*1)
Supported (*2)
*1: If any physical partition is currently operating, the crossbar box cannot be powered off.
*2: All the physical partitions must be powered off, and the system must be completely shut down.
Table 28-2
Maintenance flow
Details of update process Replacement
1 Preparation 28.3
2 Removing the cable kit 28.4
3 Installing the cable kit 28.5
4 Restoring the system 28.6
Caution -
To completely shut down the system, all the power cords must be
removed. If the power cords are not removed, an electrical failure may occur.
XSCF>
showlogs error
28.2.2 Maintenance flow
Table 28-2 lists the sequence of the maintenance procedure for the cable kit.
28.3 Enabling the Removal of the Cable Kit
This section describes the preparations that must be completed prior to removing the
cable kit.
1.
Open the r ack do or.
2.
Log in to the XSCF s hell.
3.
Execute the sho w log s command to identify th e component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm th e hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013430