Fujitsu M10-4S Server User Manual


 
XSCF>
diagxbu -y -b 00 -t 01
XSCF>
showlogs error
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
3.
Execute the diagxbu command t o d iagnose the c rossbar cables.
Diagnosis is performed when the system board of the chassis connected with the
crossbar cables is not incorporated into the physical partition, or when the
physical partition into which the chassis is incorporated is powered off.
The example below specifies the following:
00: BB-ID of the chassis to start the diagnosis
01: BB-ID of the destination where the chassis to start the diagnosis is connected
(You can specify one or more of these.)
To specify multiple connection destination BB-IDs, enter a command like
"diagxbu -y -b 00 -t 01 -t 02".
4.
Execute the sho w logs command to confirm that the system is operating
normally.
For details, see "3.3.5 Checking log information."
5.
Power on a ll the physical partitions.
For details, see "6.3 Powering On the Physical Partition Requiring Maintenance."
6.
Close t h e rack d oor.
Chapter 25 Maintaining the Crossbar Cables (Optical) 399