Fujitsu M10-4S Server User Manual


 
Please execute the following steps:
1) Confirm the XSCF STANDBY LED of BB#0 is not lit.
2) Turn off the breake r of BB#0.
3) Remove BB#0.
4) Execute either the following:
4-1) After the exchanged device is connected with the system,
turn on the breaker of BB#0, and please select 'finish'.
4-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] :
f
Chapter 6
Understanding the Preparations for
Restoring the System
This chapter describes the procedures required to restore the system after component
maintenance. See this chapter, as required, when performing maintenance on each
component described in Chapter 7 onwards.
Incorporating an FRU into the System with the replacefru Command
Incorporating a Chassis into a Physical Partition
Powering On the Physical Partition Requiring Maintenance
Starting the Entire System
Restoring the Chassis
6.1 Incorporating an FRU into the System
with the replacefru Command
This section describes the procedure for incorporating a Field Replaceable Unit (FRU)
into the system after maintenance. To do this, resume the replacefru command,
which is running, to incorporate the FRU into the system.
1.
After c o mpleting maintenance of the t arget FRU, return to the operation of the
replacefru command of th e XSCF f irmw are, and enter "f".
The following is displayed. Wait until the processing is complete.
69