Fujitsu M10-4S Server User Manual


 
XSCF>
showstatus
XSCF>
showhardconf
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
XSCF>
showstatus
XSCF>
showhardconf
normally a fter the completion of mainten an ce.
3.
Execute the sho w h ardconf command t o check the hardware configuration
and t he status of each component.
4.
Close t he rack d oor.
27.6.2 Active/Cold maintenance
1.
Connect all t h e power cords to the PSU ba ckplane unit or power supply un it
of th e chassis requiring main t enan ce.
For details, see "6.5.1 Installing the power cord."
2.
Return t o the op eration of the XSCF firm w are replacefru command to confirm
that th e XSCF DUAL control cable has b e en incorporated into the sy stem.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
3.
Execute the sho w status command to confirm that the XSCF D UAL control
cable is operating normally af t er the completion of maintenance.
4.
Execute the sho w h ardconf command t o check the hardware configuration
and t he status of each component.
5.
Close t he rack d oor.
27.6.3 Inactive/Hot maintenance
1.
Return t o the op eration of the XSCF firm w are replacefru command to confirm
that th e XSCF DUAL control cable has b e en incorporated into the sy stem.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013422