Fujitsu M10-4S Server User Manual


 
Table B-4
Specifications of XSCF unit (crossbar box) (continued)
Item Description
Maintenance category Replacement
Table B-5
Specifications of the power supply unit (SPARC M10-4/M10-4S)
Item Description
Number of power supply
units
2
Location Front of chassis
Type of maintenance Active/hot, active/cold, inactive/hot, inactive/cold, and system
stopped
Maintenance category Replacement
Table B-6
Specifications of power supply unit (crossbar box)
Item Description
Number of power supply
units
2
Location Rear of chassis
Type of maintenance Active/hot, inactive/hot, and system stopped
Maintenance category Replacement
For the maintenance procedure, see "Chapter 17 Maintaining the XSCF Unit of the
Crossbar Box."
B.4 Power Supply Unit
The power supply units of the SPARC M10-4/M10-4S and the crossbar box take
power from the input power and supply it to the system. The redundant configuration
of the power supply units allows the system to continue operating even if one of the
units fails during operation.
Table B-5 and Table B-6 list the specifications of the power supply units of the
SPARC M10-4/M10-4S and the crossbar box, respectively.
See the following chapters for details of the maintenance procedures:
SPARC M10-4/M10-4S: Chapter 10 Maintaining the Power Supply Units
Crossbar box: Chapter 18 Maintaining the Power Supply Units of the Crossbar Box
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013470