Fujitsu M10-4S Server User Manual


 
Note -
Place the removed power supply unit on a grounded antistatic ESD mat.
Note -
Do not forcibly push the power supply unit into its slot. Using excessive force may
damage the component or the chassis.
Note -
See the procedure for system-stopped maintenance for inactive/cold maintenance in a
single-chassis configuration.
10.5 Installing a Power Supply Unit
This section describes the procedure for installing a power supply unit.
10.5.1 Installing a power supply unit
1.
Support the power supply unit from b elow with one hand a nd i nsert it
carefully into its slot.
2.
Firmly pu sh the p o w er supply unit into its mounting p o sition.
3.
Close the lever a nd t hen tighten the sc rews.
4.
Connect the power c ord s to the power supply unit.
10.5.2 Restoring the chassis
1.
Connect the power c ord s to the PSU b a ckplane unit of the ch assis requiring
maintenance.
2.
Confirm th at the LE D (green) on the po wer supply unit is blinking.
3.
Install the front cover.
For details, see "6.5.3 Installing the front cover."
10.6 Restoring the System
This section describes the procedure for restoring the system after installing a power
supply unit. The restoration procedure differs depending on the maintenance type as
follows:
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual