Fujitsu M10-4S Server User Manual


 
Caution -
To completely shut down the system, all the power cords must be
removed. If the power cords are not removed, an electrical failure may occur.
Note -
Active/hot maintenance is supported only for a redundant configuration.
XSCF>
showlogs error
XSCF>
replacefru
of a power supply unit. The preparation procedure differs depending on the
maintenance type as follows:
Active/Hot maintenance
Inactive/Hot maintenance
System-stopped maintenance
18.3.1 Active/Hot maintenance
1.
Open the r ack do or.
2.
Log in to the XSCF s hell.
3.
Execute the sho w log s command to identify th e component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm th e hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Execute the replacefru command t o release th e power supply unit requiring
maintenance from the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
6.
Remove the power cord from the po w er supply u nit requiring maintenance.
For details, see "5.5.2 Removing the power cord."
18.3.2 Inactive/Hot maintenance
1.
Open the r ack do or.
2.
Log in to the XSCF s hell.
3.
Execute the sho w log s command to identify th e component requiring
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013320