Fujitsu M10-4S Server User Manual


 
XSCF>
showlogs error
XSCF>
replacefru
Note -
In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
Caution -
Before you handle any components, wear a wrist strap to ground any static
electricity. If you perform this procedure without a wrist strap, individual
components or the overall system may be damaged. For details, see "1.5 Notes
Regarding Static Electricity."
2.
Log in to the XSCF s hell.
3.
Execute the sho w log s command to identify th e component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm th e hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Stop t h e entire system.
For details, see "5.4 Stopping the Entire System."
6.
Execute the replacefru command to releas e the chassis requiring m aint ena nce
from th e system.
For a single-chassis configuration, you do not have to release the chassis.
Proceed to step 7.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7.
Remove all the po w er cords from the P SU backplane unit of the chassis
requiring mai nten ance.
For details, see "5.5.2 Removing the power cord."
11.4 Removing a Fan Unit
This section describes the procedure for removing a fan unit. Complete the necessary
preparations prior to attempting the removal. For details, see "11.3 Enabling the
Removal of a Fan Unit."
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013212