Fujitsu M10-4S Server User Manual


 
XSCF>
showdomainstatus -p 0
Logical Domain Name Status
primary Solaris running
4S-159-D0-G0 Solaris running
4S-159-D0-G1 Solaris running
4S-159-D0-G2 Solaris running
XSCF>
showboards -a
PSB PPAR-ID(LSB) Assignment Pwr Conn Conf Test Fault
---- ------------ ----------- ---- ---- ---- ------- --------
00-000(00) AssignedyyyPassedNormal
01-000(01) AssignedyyyPassedNormal
XSCF>
poweroff -p 0
PPAR-IDs to power off:00
Continue? [y|n] :
y
00 : Powering off
XSCF>
showpparstatus -p 0
PPAR-ID PPAR Status
00 Powered Off
6.
Execute the sho w bo ards command t o check the state of the chassis requiring
maintenance.
The BB-ID of the chassis requiring maintenance is indicated by the system board
(PSB) number.
In the following example, we can see that [PPAR-ID] of PSB 01-0 is "00".
7.
Execute the po w eroff command t o stop a ll the logical domains on th e
physical partition req uiring maintenance.
In response to the confirmation message, enter "y".
8.
Execute the showpparstatus command to c onfirm that the p ower t o t he
physical partition is turned o ff.
In the following example, [PPAR Status] of PPAR-ID 00 displays "Powered Off",
which indicates that the power to the physical partition has been turned off.
9.
Switch the mod e switches for the master cha ssis and tho se chassis whos e
XSCFs are in the standby state to Service mo d e.
-
For a building block configuration (w ithout crossbar bo x)
Switch the mode switches of BB-ID#00 and #01 to Service mode.
-
For a building block configuration (w ith crossbar bo x)
Switch the mode switches of BB-ID#80 and #81 to Service mode.
Chapter 5 Understanding the Preparations for Enabling Maintenance 61