Fujitsu M10-4S Server User Manual


 
Note -
Install the power supply units in their original positions by referring to the notes that
you made prior to the start of maintenance.
Note -
Reinstall the fan units in their original locations by referring to the notes you made
prior to the start of maintenance.
Note -
Reinstall the internal disks in their original locations by referring to the notes that you
made prior to the start of maintenance.
Note -
If no crossbar unit is mounted, proceed to step 10.
Note -
Reinstall the PCIe card cassettes in their original positions by referring to the notes
that you made prior to the start of maintenance.
14.5.2 Restoring the chassis
1.
Install the fan sh elf and then tighten the two screws i n the fan slot.
2.
Install all the po wer supply units .
For details, see "10.5.1 Installing a power supply unit."
3.
Install all the fan units.
For details, see "11.5.1 Installing a fan unit."
4.
Install all the internal disks or HDD filler uni t s.
For details, see "12.5 Installing an Internal Disk."
5.
Install the front cover.
For details, see "6.5.3 Installing the front cover."
6.
Insert th e CPU memory unit i n the c ha ssis.
7.
Raise the ri ght and left levers of the C P U memory u nit and then tighten the
one screw.
8.
Install the mounting fr ame for the crossbar un it and then tighten th e three
screws.
9.
Install all the crossbar units.
For details, see "9.5.1 Installing a crossbar unit."
10.
Install all the PCIe card cassettes.
For details, see "13.6.2 Installing a PCI Express card cassette."
11.
Connect all the cables to the external interface.
Thecablestobeconnectedareasfollows.
Interface cable connected to the PCIe card
Chapter 14 Maintaining the PSU Backplane Unit 275