Fujitsu M10-4S Server User Manual


 
Note -
Inthecaseofadualpowerfeed,makeanoteofthelocationsofthepowercords
before disconnecting them to ensure that they are reinstalled correctly.
XSCF>
replacefru
Note -
Inthecaseofadualpowerfeed,makeanoteofthelocationsofthepowercords
before disconnecting them to ensure that they are reinstalled correctly.
Caution -
Before you handle any components, wear a wrist strap to ground any static
electricity. If you perform this procedure without a wrist strap, individual
components or the overall system may be damaged. For details, see "1.5 Notes
Regarding Static Electricity."
12.3.5 System-stopped maintenance
1.
Open the r ack d oor.
2.
Confirm t he hardware and s oftw are configurations.
For details, see "4.2 Confirming the System Configuration."
3.
Stop t he entire syste m.
For details, see "5.4 Stopping the Entire System."
4.
Execute the replacefru command to release the chassis requiring m aintenance
from t he system.
For a single-chassis configuration, you do not have to release the chassis.
Proceed to step 5.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
5.
Remove all the power cords from the P SU backplane unit of the chassis
requiring maintenance.
For details, see "5.5.2 Removing the power cord."
12.4 Removing an Internal Disk
This section describes the procedure for removing an internal disk. Perform
reduction using the same procedure.
Make the internal disk ready for removal before attempting to remove it. For details,
see "12.3 Enabling the Removal of an Internal Disk."
Chapter 12 Maintaining the Internal Disks 231