Fujitsu M10-4S Server User Manual


 
Table 4-6
Types of maintenance for SPARC M10-4S (continued)
Supported: Maintenance can be performed / Unsupported: Maintenance cannot be performed
FRU Active/hot Active/cold Inactive/hot
Inactive/cold (*1)
System stopped Reference
Operation panel Unsupported Supported
(*2)
Unsupported Supported Supported Chapter
15
*1: For a single-chassis configuration, the inactive/cold maintenance procedure is the same as that for stopping the system, therefore see
the procedure for system-stopped maintenance.
*2: It is necessary to use dynamic reconfiguration (DR) to disconnect a chassis requiring maintenance from the physical partition.
*3: Active/hot replacement can be performed only with a redundant configuration.
*4: Supported only for internal disks of devices other than boot devices. If, however, the boot device has a redundant configuration
(RAID configuration), active/hot maintenance is supported.
*5: The types of maintenance for PCIe cards are different from those of other FRUs. For details, see Table 13-1.
Table 4-7
Types of maintenance for crossbar box
Supported: Maintenance can be performed / Unsupported: Maintenance cannot be performed
FRU Active/hot Active/cold Inactive/hot Inactive/cold System stopped Reference
Crossbar unit Unsupported Supported
(*1)
Unsupported Supported Supported
(*3)
Chapter
16
XSCF unit Supported
(*4)
Unsupported
(*2)
Supported Unsupported
(*2)
Supported
(*3)
Chapter
17
Power supply unit Supported
(*5)
Unsupported
(*2)
Supported Unsupported
(*2)
Supported
(*3)
Chapter
18
Fan unit Supported Unsupported
(*2)
Supported Unsupported
(*2)
Supported
(*3)
Chapter
19
XSCF interface unit Unsupported Unsupported
(*2)
Unsupported Unsupported
(*2)
Supported
(*3)
Chapter
20
Crossbar backplane
unit
Unsupported Unsupported
(*2)
Unsupported Unsupported
(*2)
Supported
(*3)
Chapter
21
Fan backplane Unsupported Unsupported
(*2)
Unsupported Unsupported
(*2)
Supported
(*3)
Chapter
22
Operation panel Unsupported Unsupported
(*2)
Unsupported Unsupported
(*2)
Supported
(*3)
Chapter
23
*1: If any physical partition mounted on two or more chassis is currently operating, the crossbar box cannot be powered off.
*2: If any physical partition is currently operating, the crossbar box cannot be powered off.
*3: All the physical partitions must be powered off, and the system must be completely shut down.
*4: The XSCF must be configured as a slave before maintenance is started. If the XSCF is operating as the master XSCF, switch it to a
standby XSCF.
*5: Active/hot replacement can be performed only with a redundant configuration.
Table 4-8
Types of maintenance for cables and dedicated power distribution unit
Supported: Maintenance can be performed / Unsupported: Maintenance cannot be performed
FRU Active/hot Active/cold Inactive/hot Inactive/cold System stopped Reference
Crossbar cable
(electrical)
Unsupported Unsupported Unsupported Supported Supported Chapter
24
Crossbar cable
(optical)
Unsupported Unsupported Unsupported Supported Supported Chapter
25
Chapter 4 Preparing for Maintenance 51