Fujitsu P3NK-4452-01ENZD Computer Hardware User Manual


 
XG Series User's Guide Chapter 5 Command Reference
Port Information Settings
118
Default It is assumed that "manual" was specified for releasing the offline state operation of the
linked port list.
5.1.1.28 linkaggregation downrelay recovery cause
Function Set the target parameters for offline state release in the Linkdown Relay function of the
linkaggregation.
Available Model XG0224 / XG0448 / XG2600
Syntax linkaggregation <group> downrelay recovery cause <cause>
Options
<group>
Link aggregation group number
Set a link aggregation group number with a decimal number.
<cause>
Specify the offline parameters targeted to offline state release of the linked port from the
following.
downrelay
Specify when offline parameters by the Linkdown Relay function are targeted for
release.
all
Release offline state of all parameters.
Use Mode Configuration mode (admin class)
Explanation Set the offline parameters lead by linkup assigned for releasing the offline state when
"auto" is specified in the "ether downrelay recovery" command.
Caution
This command is enabled only when "auto" is set for offline state release operation
("ether downrelay recovery mode" command) lead by linkup.
The definition is ignored when "manual" is specified.
The offline state is released independent of this command definition when the "online"
command in the linked port is executed, or during dynamic definition change
accompanied by releasing the offline state.
Default It is assumed that "downrelay" was specified as the target parameters for offline state
release of the linked port list.
linkaggregation <group> downrelay recovery mode manual
Range Model
1 to 13 XG0224
1 to 26 XG0448
1 to 10 XG2600
linkaggregation <group> downrelay recovery cause downrelay