XG Series User's Guide Chapter 6 Managing the Device
Actions When Firmware Update Failes (Backup Firm Function)
574
6.4 Actions When Firmware Update
Failes (Backup Firm Function)
If the firmware update fails due to power failure or some other reason and you cannot start this device, you can restore the
device to its normal condition by starting the backup firmware and transferring the firmware with an FTP client on the
network or by a compact flash card.
6.4.1 Preparing the Device
Precautions
When the device boots up Backup Firm, the IP address of Management-port (XG2600) or LAN port (XG0224 /
XG0448) is set 192.168.1.1.
A problem has come up, so please connect only this device and a PC.
1. Make sure that the power of this device is turned off.
2. Connect this device and a PC via LAN.
•XG2600
Directly connect a cable to Management Port (10/100BASE-TX port) of this device and the PC instead of using a HUB
in between.
• XG0224 / XG0448
Directly connect a cable to 10/100/1000BASE-T ports of this device and the PC instead of using a HUB in between.
Note
Management-port of XG2600 (10/100BASE-TX) is MDI fixed.
Note
As this device supports AutoMDI/MDI-X function, you can connect a cable to 10/100/1000BASE-T ports without being
conscious of the PC and HUB.