Fujitsu P3NK-4452-01ENZD Computer Hardware User Manual


 
XG Series User's Guide Chapter 6 Managing the Device
Verifying the Device Operations
549
When a SFP+ Card is installed.
1) Current time
Present date and time.
2) Startup time
Date and time when the system started up.
3) restart_cause
Cause for the system startup.
The following system startup causes are displayed:
power on : The power has been turned on.
reset : The reset command has been issued.
reset switch : The [RESET] switch has been pressed.
system down : System-down has occurred.
4) machine_state
State of the device
RUNNING : The device is active.
5) power0_state
State of the power unit.
NORMAL : The power unit works normally.
NO_PRESENT : The power unit is not installed.
FAIL : The power unit has been turned off.
UNKNOWN : The power unit is invalid state.
6) fan0_state
State of the fan 0.
NORMAL : The fan works normally.
ABNORMAL : The fan has been abnormal.
UNKNOWN : The fan is invalid state.
7) inspiration_state
State of environment temperature monitor.
phy_state
State of temperature monitor around PHY.
slot1_state
State of Expansion Card temperature monitor (SLOT1).
# show system status
Current-time : Wed Dec 10 06:03:04 2008 ---(1)
Startup-time : Wed Dec 10 06:02:19 2008 ---(2)
restart_cause : reset ---(3)
machine_state : RUNNING ---(4)
power0_state : NORMAL ---(5)
fan0_state : NORMAL ---(6)
inspiration_state : NORMAL ---(7)
phy_state : NORMAL
slot1_state : NORMAL
inspiration_temp : 25 C ---(8)
phy_temp : 39 C
slot1_temp : 39 C
Slot Information
slot1 : SJ10GSFPZ ---(9)