Workflow for Initial Setup of the Device
56
3.1 Workflow for Initial Setup of the Device
This section describes the procedures to setup the device.
1) Prepare a terminal
Prepare a terminal for the initial configuration.
2) "Besic Setting Up"
Connect the device and terminal with an RS232C cable. The band rate setting is 9,600 bps.
To configure the Device basically, carry out the following procedure.
3) Turn on the device to start the system.
Turn on the terminal and the device to start the system.
4) "Configure LAN Interface"
The initial setting of the LAN interface is for only IPv6 link-local address.
To use the following functions, set up the LAN interface:
- Telnet connection
- SNMP manager connection
- System log transmission
- Time synchronization using an NTP/SNTP server
- Configuration file upload/download
- Firmware update
- Collection of maintenance information
5) "Telnet Connection via the LAN Interface (Optional)"
The initial setting of the Telnet connection via the management LAN interface is disabled.
Enable telnet connection if necessary.
6) "SNMP Configuration (Optional)"
Initially, the SNMP agent configuration is not set.
Set the SNMP configuration as needed.
7) This is the end of the preparation procedure
Proceed with configuring the switch.
Command Task
Login:admin
Password:
Login to the device from the serial terminal. The user name is
"admin". The default password is not set.
XG2600# configure Switch to Configuration mode.
XG2600(config)# sysname HOST-NAME Set the device name (HOST-NAME).
XG2600(config)# time zone -0500 Set time zone.
XG2600(config)# date YYYY/MM/DD.hh:mm:ss Set date and time.
XG2600(config)# password admin set
Password:
Retype password:
Set the password for user "admin".
Type password.
Retype password.
XG2600(config)# save Save the configuration.