XG Series User's Guide Chapter 5 Command Reference
Device Information Settings
287
5.15.3.2 time auto interval
Function Set an automatic setting interval of time information.
Available Model XG0224 / XG0448 / XG2600
Syntax time auto interval <time>
Options
<time>
Specify the interval to set time information.
start
Specify when setting time information only once at device power-on or restart.
Interval
Specify the interval to set time information within the range of 0 second up to 10 days.
The unit shall be d (day), h (hour), m (minute), or s (second).
Use Mode Configuration mode (admin class)
Explanation Set an interval to automatically set the time.
Default It is assumed that time information is set only once at device power-on or restart when
using the time supply server.
5.15.3.3 time zone
Function Set the time zone of time information.
Available Model XG0224 / XG0448 / XG2600
Syntax time zone <offset>
Options
<offset>
Difference
Specify the time zone of this device.
Specify the time differences from Greenwich Mean Time (GMT).
Use Mode Configuration mode (admin class)
Explanation Set the timezone.
Default It is assumed that Greenwich Mean Time (GMT) is set for the time zone.
time auto interval start