Fujitsu P3NK-4452-01ENZD Computer Hardware User Manual


 
XG Series User's Guide Chapter 6 Managing the Device
Verifying the Device Operations
550
NORMAL : The temperature is normal.
HIGHWARNING : The device changes to a high temperature state.
HIGHALARM : Thermal alarm occurs in the device.
UNKNOWN : There are three following states.
The Expantion Card without Thermal Sensor is installed. (CX4).
The Invalid Expantion Card is installed.
The Expantion Card is not installed.
8) inspiration_temp
Environment temperature.
phy_temp
temperature around PHY.
slot1_temp
temperature around Expansion Card (SLOT1).
At the time of three following states, "--" is displayed.
The Expantion Card without Thermal Sensor is installed. (CX4)
The Invalid Expantion Card is installed.
The Expantion Card is not installed.
9) Slot Information
The type of Expansion Card.
SJ10GCX4Z : Installed Expansion Card is SJ10GCX4Z. (CX4)
SJ10GSFPZ : Installed Expansion Card is SJ10GSFPZ. (SFP+)
NO_PRESENT : The Expantion Card is not installed.
UNKNOWN : Installed Expansion Card is Invalid Card.
XG0448
When a CX4 Card is installed in Slot 1 and a SFP+ Card is installed in Slot 2.
1) Current time
Present date and time.
2) Startup time
Date and time when the system started up.
# show system status
Current-time : Tue Dec 9 20:43:01 2008 ---(1)
Startup-time : Tue Dec 9 20:42:48 2008 ---(2)
restart_cause : power on ---(3)
machine_state : RUNNING ---(4)
power0_state : NORMAL ---(5)
power_consumption : 79 W ---(10)
fan0_state : NORMAL ---(6)
fan1_state : NORMAL
fan2_state : NORMAL
inspiration_state : NORMAL ---(7)
phy_state : NORMAL
slot1_state : UNKNOWN
slot2_state : NORMAL
inspiration_temp : 31 C ---(8)
phy_temp : 38 C
slot1_temp : -- C
slot2_temp : 29 C
Slot Information
slot1 : SJ10GCX4Z ---(9)
slot2 : SJ10GSFPZ