Fujitsu P3NK-4452-01ENZD Computer Hardware User Manual


 
XG Series User's Guide Chapter 5 Command Reference
LLDP Information Settings
226
5.9.1.2 lldp send hold
Function Set LLDP hold times
Available Model XG0224 / XG0448 / XG2600
Syntax lldp send hold <count>
Options
<count>
LLDP hold times
Specify LLDP hold time which neighbor device holds LLDP information of this device.
Specify LLDP hold times with a decimal value from 2 times to 10 times.
This setting corresponds to msgTxInterval in 802.1AB
This setting corresponds to msgTxHold in 802.1AB
Use Mode Configuration mode (admin class)
Explanation Specify LLDP hold time which neighbor device holds LLDP information of this device.
Default It is assumed that 4 is set for LLDP hold times.
5.9.1.3 lldp reinit delay
Function Set LLDP reinit delay time
Available Model XG0224 / XG0448 / XG2600
Syntax lldp reinit delay <delay>
Options
<delay>
LLDP reinit delay time
When LLDP send function is disabled, this device sends LLDP information with TTL=0
and after <delay> time, this device reinitializes the internal status.
This setting corresponds to reinitDelay in 802.1AB
Use Mode Configuration mode (admin class)
Explanation When LLDP send function is disabled, this device sends LLDP information with TTL=0
and after <delay> time, this device reinitializes the internal status.
Default It is assumed that 2sec is set for LLDP reinit delay time.
lldp send hold 4
lldp reinit delay 2s