Fujitsu P3NK-4452-01ENZD Computer Hardware User Manual


 
XG Series User's Guide Chapter 5 Command Reference
System Operations and Display Commands
359
3) restart_cause
Cause for the system startup.
The following system startup causes are displayed:
power on : The power has been turned on.
reset : The reset command has been issued.
reset switch : The [RESET] switch has been pressed.
system down : System-down has occurred.
4) machine_state
State of the device
RUNNING : The device is active.
FALLBACK : The device is into fallback state.
5) access_direction
Direction where a device is installed in.
front access : The device should be installed forward.
rear access : The device should be installed backward.
6) power_redundancy
State of the redundant power unit.
single : The device has no redundant power unit.
redundant : The device has a redundant power unit.
7) PSU1 state
State of the power unit (PSU1).
PSU2 state
Type of the power unit (PSU2).
NORMAL : The power unit works normally.
NO PRESENT : The power unit is not installed.
NO POWER : The power unit has been turned off.
FAIL : The power unit has been abnormal.
UNKNOWN : The power unit is invalid type.
WARNING : The power unit has been incorrectly mounted.
8) PSU1 type
Type of the power unit (PSU1).
PSU2 type
Type of the power unit (PSU2).
AC : The power unit is AC.
-- : The power unit is not installed or invalid type.
9) power_consumption
Power consumption of the device.
10) FAN1 state
State of the fan module 1.
FAN2 state
State of the fan module 2.
NORMAL : The fan module works normally.
FAIL : The fan module has been abnormal.
NO PRESENT : The fan module is not installed.
UNKNOWN : The fan module is invalid direction.