5 - 23
Input
condition
DS
K16D32D0BMOVP
n
BMOV
When the input condition is turned on, the BMOV instruction transfers the data in
the devices starting from the device specified in
S
to the devices starting from
the device specified in
D
in batch (the numbers of source devices and target
devices are specified by
n
).
Example
The BMOV instruction executes the following operation when X5 is
turned on.
S
365
D0 365 D32
D
365D7 365 D39
7000D8 7000 D40
7000D15 7000 D47
The BMOV instruction is useful for the following:
• Filing logging data
• Saving important data (such as automatic operation data and measured data)
into the latch area. This can prevent a data loss caused by a power failure.
Applicable device
Internal device
(system or user)
File
register
MELSECNET/10
(H) Direct Jn\
Index
register
Constant
Pointer
Level
Bit Word R Bit Word
Intelligent
function
module
Un\G
Z K H P I N
Digit
Number of basic
ste
p
s
S
(Note)
(Note)
(Note)
D
FMOV
S D
n
BMOV
S D
n
n
K1
to
K4
4
(Note) Not available in the BMOV instruction.