Mitsubishi Electronics 13JW55 Network Card User Manual


 
6 - 4
6.1.2 Setting and resetting the device "M"
Activate the CPU before this operation.
1) Click [Debug] [Modify Value].
1) Click!
2) Enter "M10"!
3) Click!
2) The Modify Value dialog box is displayed.
Enter "M10" in the "Device/Label" list box.
3) Click the ON
or OFF button to set or
reset "M10".
Check with demonstration machine
(Monitor screen when M10 is set)
4
T0
K4
K1500
X4
M10
BCD T0 Y50
Turn off X4 and check the following.
1) When M10 is set,
M10
becomes non-conductive and the current value
of the timer T0 is cleared to 0.
Check that the value on the digital display (Y50-Y5F) does not change.
2) When M10 is reset,
M10
is conducted and the timer T0 starts counting
from 0. This count value increases every 10 seconds.
Confirm that the value on the display (Y50-Y5F) increases every 10
seconds.
POINT
With the same procedure, bit devices other than the internal relay (M) also can
be set or reset forcibly.