Mitsubishi Electronics 13JW55 Network Card User Manual


 
5 - 48
(From the previous page)
7) Select!
8) Click!
7) Click [Online] [Write to PLC] to display the
Online Data Operation dialog box. Select
"Parameter" in the PLC Module tab.
8) Click the Execute
button to write the
data.
To clear the file register data with the program, write the following program.
For the operation procedure, refer to section 4.4.
Turning on X0 can write the data, and turning on X1 can clear the data.
Project name File register
Program name MAIN
X0
R5
K173
0
MOV
X1
R5
K0
3
MOV
The file register data of the standard RAM
is kept by the battery.
Resetting or turning off the power cannot
clear the data. To clear the data, write "0".
X0
D5
K1736MOV