Mitsubishi Electronics 13JW55 Network Card User Manual


 
App. - 23
Project name QA-4
Program name MAIN
X0
M0
D1K100-
0
12
Outputs error when
set value is 100 or less
D1D0MOV
D2D0MOV
D2K50-
Setting
Reads set value
ON during operation
Turns on at 100 before
the set value
Counter that turns on
at stop
M0SET
X1
2
M0RST
M0
4
D0K4X20BIN
Y70D0K100>
Y70
X5
24
Y71
C0
Y71
Y71
28
M3N0MC
X3
31
C0
D0
C1
D1
C2
D2
44
N0MCR
X1
45
C0RST
C1RST
C2RST
M0
58
K4Y60C0BCD
C1
62
Y72
C2
64
Y73
C0
66
Y74
Set value -100
(100 short of set value)
Set value -50
(50 short of set value)
Counter that turns on
100 short of set value
Counter that turns on
50 short of set value
Counter is reset by
turning on X1
Displays counted
values to exterior
Turns on at 50 before
set value
Turns on by count up
Note) In GX Works2, the on/off status of the master control is displayed in the title
tag on the monitor screen.