App. - 39
Operation pattern from manual to automatic operation
Teaching panel
Coating bath
X00 = Manual right moving button
X01 = Manual left moving button
X02 = Manual cleaning button
X03 = Recording data button
X05 = Reading data button
X06 = Automatic operation button
X07 = Operation stop button
Y73 = Automatic operation
indication LED
X20 = Coating bath-1 (K2X20 = K1)
X21 = Coating bath-2 (K2X20 = K2)
X22 = Coating bath-3 (K2X20 = K4)
X23 = Coating bath-4 (K2X20 = K8)
X24 = Coating bath-5 (K2X20 = K16)
X25 = Coating bath-6 (K2X20 = K32)
Start moving to right (X00 = ON)
Stop moving to right (X00 = OFF)
Start cleaning (X02 = ON)
Finish cleaning (X02 = OFF)
Start moving to right (X00 = ON)
Stop moving to right (X00 = OFF)
Start cleaning (X02 = ON)
Finish cleaning (X02 = OFF)
Start moving to right (X00 = ON)
Stop moving to right (X00 = OFF)
Start cleaning (X02 = ON)
Finish cleaning (X02 = OFF)
Start moving to left (X01 = ON)
Stop moving to left (X01 = OFF)
Start cleaning (X02 = ON)
Finish cleaning (X02 = OFF)
Start moving to right (X00 = ON)
Stop moving to right (X00 = OFF)
Start cleaning (X02 = ON)
Finish cleaning (X02 = OFF)
Start moving to right (X00 = ON)
Stop moving to right (X00 = OFF)
Start cleaning (X02 = ON)
Finish cleaning (X02 = OFF)
Start automatic operation
(X06 = ON ? OFF)
Automatic operation indication LED
(Y73 = ON)
Cleaning machine
Y70 = Conveyor, Moving right
Y71 = Conveyor, Moving left
Y72 = Conveyor, Cleaning
Moving to right (Y70 = ON)
Stop moving (Y70 = OFF)
Cleaning (Y72 = ON)
Stop cleaning (Y72 = OFF)
Moving to right (Y70 = ON)
Stop moving (Y70 = OFF)
Cleaning (Y72 = ON)
Stop cleaning (Y72 = OFF)
Moving to right (Y70 = ON)
Stop moving (Y70 = OFF)
Cleaning (Y72 = ON)
Stop cleaning (Y72 = OFF)
Moving to left (Y71 = ON)
Stop moving (Y71 = OFF)
Cleaning (Y72 = ON)
Stop cleaning (Y72 = OFF)
Moving to right (Y70 = ON)
Stop moving (Y70 = OFF)
Cleaning (Y72 = ON)
Stop cleaning (Y72 = OFF)
Moving to right (Y70 = ON)
Stop moving (Y70 = OFF)
Cleaning (Y72 = ON)
Stop cleaning (Y72 = OFF)
Moving to left (Y71 = ON)
(Starts the automatic operation)
A
The same operation is repeated from (A).
A
2)
3)
4)
5)
6)
1)
Standby position (K2X20 = 0)
Coating bath-1 (K2X20 = 1)
Coating bath-2 (K2X20 = 2)
Coating bath-4 (K2X20 = 8)
Coating bath-3 (K2X20 = 4)
Coating bath-5 (K2X20 = 16)
Coating bath-6 (K2X20 = 32)
Coating bath-1 (K2X20 = 1)