5 - 50
Operation Practice
(1) External setting of the timer set value and display of the current value
• Set the timer set value in the digital switch (X20 to 2F), and turn on the switch
X0.
• When the switch X4 is turned on, Y70 turns on after the time specified with
the digital switch. (For example, Y70 turns on after 123.4sec.
when is set.)
• The digital display (Y40 to 4F) displays the current value of the timer T10.
(2) External setting of the counter set value and display of the current value
• Set the counter set value in the digital switch (X30 to 3F), and turn on the
switch X1.
• Turn on and off the switch X5 repeatedly. When X5 has turned on for the
times specified with the digital switch (count up), Y71 turns on.
• The digital display (Y50 to 5F) displays the current value of the counter C10
(the number of times that X5 is turned on).
• Turning on the switch X6 clears the counter C10 to 0. When the contact C10
is already turned on (count up), the contact is released.
1 2 3 4