Nortel Networks N0060600 Webcam User Manual


 
Chapter 16 Configuring Hospitality services 111
BCM 4.0 Device Configuration Guide
Hospitality - Rooms
The Hospitality - Rooms panel allows you to assign telephones to a room. You can assign a
maximum of five telephone DNs to a room.
Room condition password <up to six digits> Set the password that allows access to the
Room condition feature (FEATURE 876).
Default password: None
!
Nortel strongly recommends that you change the default password, and
frequently change the desk password to prevent unauthorized entry.
Call Restrictions
Vacant filter <two-digit filter #> Enter a code that indicates which calls are
allowed when a room is empty (for
example, 911).
Basic filter <two-digit filter #> Enter a code that indicates which calls are
allowed for a basic room telephone. (for
example 911, and internal calls only)
Mid filter <two-digit code> Enter a code that indicates which calls are
allowed for a telephone with mid service. (for
example 911, internal calls, and 1-800
numbers only)
Full filter <two-digit code> Enter a code that indicates which calls are
allowed for a telephone with full service. (i.e.
no restrictions)
Wake-Up Call Settings
Attempts <1-5> Select the number of times the Alarm time
feature attempts to alert the occupant before
cancelling.
Default: 3
Retry interval 2, 4, 6, 8 (minutes) Select the interval between each attempt to
send the alarm.
Default: 4
Alarm duration (sec.) 10, 15, 20, 25, 30, 35, 40, 45,
50 (seconds)
Select the period that a telephone rings for
each alarm attempt.
Default: 15
Expired Wake-Up Call Settings
Notify DN None/DN: <telephone DN> Enter a telephone DN if you want to notify a
specific telephone when an alarm expires.
Use tone <check box> Select if you want the user to hear a tone
when the alarm expires.
Table 36 Hospitality main settings (Sheet 2 of 2)
Field Values Description