Chapter 6 DN records parameters 63
BCM 4.0 Device Configuration Guide
Figure 19 Capabilities and Preferences - ATA Settings panel fields
Use the information in Table 18 to configure ATA settings.
Table 18 ATA settings
Attribute Values Description
ATA answer
timer
3, 5, 7, 10 Select the length of delay between the time you dial the last digit and when the
analog device is ready to receive DTMF tone.
Default: 7
ATA tones <check box> Not selected: No tones occur when a message is received (use for data equipment).
Selected: Tones occur when a message is received (use for analog telephones).
Default: Cleared
ATA use On site
Off site
Select the location of the ATA2.
Note: Set the field to On site for all installations, except devices on a long loop. Set
the field to Off site to increase the audio level to devices that are remote to the
ATA2. This field has no effect for ASM and ASM8+ devices.
Note: OPX connections are not supported.
Default: On site
Msg indicate None
Tone
Lamp
Select Tone to send a Message Tone through the telephone receiver when you
receive a message.
Select Lamp to turn on the Message Lamp when you receive a message.
Default: None
ATA device Modem
Telephon
Devices connected to the system through an ATA can have connectivity issues over
BRI/PRI lines. To alleviate this, you can specify the type of device attached to the
analog line.
Modem supports 3.1 kHz audio, which requires a higher quality of service on the
ISDN trunks that modems and FAX machines require for reliable information
transfer. If the trunks cannot provide the higher level of service, the call fails.
Telephon supports speech paths, which require less quality on the trunk; if used for
FAX and/or modem, information transfer is unreliable.
Default: Modem
Disconnect
supervision
<check box> If you have a modem or fax machine that does not disconnect automatically when
the caller disconnects, you can select this feature; the system then disconnects the
line from the device when it receives the disconnect signal from the far end. This
feature is supported only by ASM8+ modules.
Note: The line must be configured as supervised/guarded. Refer to “Properties” in
the BCM 4.0 Networking Configuration Guide (N0060606).
Default: Cleared