Parker Hannifin G2 Computer Drive User Manual


 
8-21
(2) Operation
The motor can be operated when the operation mode is set to the RS232C operation enable mode (see Chapter 5).
(When the RS232C operation disable mode is set, some buttons are disabled.)
[Start]
1) Set the motor to Servo ON (see Chapter 5).
2) Click “Start (D).”
The measured value of the homing is displayed after the homing operation is finished.
[Abort]
1) Click “Abort (A).”
The motor decelerates and stops.
[Error Reset]
1) Click “ErrReset (R).”
Errors that can be recovered are canceled.
[Simplified terminal]
1) Click “Terminal (T).”
2) Send or receive character strings.
8