Parker Hannifin G2 Computer Drive User Manual


 
5-20
Functions
5
5.7.3 Auto Conversion and Clear Functions When Changing Simplified Scaling
Weighted Data
When simplified scaling weighted data is changed, the following parameters are automatically converted:
[Related parameters]
#9 Feeding velocity
#10 Jog velocity
#11 Over-travel search velocity during a homing move
#12 Homing operation: Home sensor proximity signal search velocity
#13 Homing operation: Home sensing feed velocity 1
#15 Homing operation: Origin position offset move feed velocity
#29 Offset distance from the Home position
#31 Operation width under testing mode
#32 Operation width under Auto-tuning
#58 Positioning setting width
#45 Positioning setting width2
#46 Positioning setting width3
#47 Positioning setting width4
#213 Maximum velocity
5.7.4 Limiting the Maximum Parameter Values
Limit processing is performed for the following parameters related to velocity at the time of parameter entry and
when the power is turned ON.
[Related parameters]
#9 Feeding velocity
#10 Jog velocity
#11 Over-travel search velocity during a homing move
#12 Homing operation: Home sensor proximity signal search velocity
#13 Homing operation: Home sensing feed velocity1
#15 Homing operation: Origin position offset move feed velocity
[At the time of parameter entry]
If a parameter value exceeds #357 Maximum velocity monitor value when it is set by the user, it will be
processed as out of range data. However, limit processing is not performed in the hold-on state (while
downloading parameters), when changing the simplified scaling weighted data, or when changing the maximum
velocity data.
[When the power is turned ON]
During processing when the power is turned ON after simplified scaling weighted data or maximum velocity
data is changed, a limit is applied using the value equivalent to the #357 Maximum velocity monitor that is
successively initialized.