Parker Hannifin G2 Computer Drive User Manual


 
3-7
Specification
Cable
DM1004B/1004C Other DM/DR series
!
0.5 mm
2
or more, 30 m or less in length
!
2.0 mm
2
or more, 30 m or less in length
AC power
supply cable
! Clamping torque of terminal: 12[kgf-cm
2
](1.18[Nm])
(terminal screw: M4x0.7)
! Power supply filter, recommended part: Tokin Corporation #LF-200 series
! 0.5 mm
2
or more, 15 m or less in length ! 2.0 mm
2
or more, 30 m or less in length
!
Optional cable: CM6000C-
"""
! Optional cable: CM300M-""" or
CM0300R-"""
Motor cable
!
0.5 mm
2
or more (use as thick cable as possible)
!
2.0 mm
2
or more (use as thick cable as
possible)
Ground cable
! Third grade ground (ground resistance 100 or less)
Jumper wire ! 2.0 mm
2
or more
For 100V: 80W 60
Regenerative
resistance*
For 200V: 80W 200
* Only for models with regenerative resistance (500W level)
3