Parker Hannifin G2 Computer Drive User Manual


 
Error number 5 Kernel error
Error type: [KIND_SYS] System error
Measures: [TYPE_ELS] Others
Long:
Short:
KernelError
KernelErr
Main cause: An error that should have not occurred in driver software has occurred.
[Subcode]
1: Axis operation handshake error
2: System program error
Action to take: Contact us.
Error number 10 Data sum error
Error type: [KIND_POR] Start-up error
Measures: [TYPE_POR] Do not start up.
Long:
Short:
DataSumError
DataSumErr
Main cause: Destroyed data was detected during data check when the power was turned on.
[Subcode]
1: Parameter file
2: Parts data file
3: Program file
4: Index correction file
5: I/O logic setting file
6: Index file Type B
7: Absolute accuracy compensation file
Action to take: Perform the Reset All operation, and download all backup data.
Error number 11 Data error
Error type: [KIND_POR] Start-up error
Measures: [TYPE_POR] Do not start up.
Long:
Short:
DataError
DataError
Main cause: Data that cannot be processed was detected when the power was turned on.
[Subcode]
1: Basic data and adjustment data problem
2: Servo constant problem
Action to take: Contact us.
Error number 15 Encoder error
Error type: [KIND_SYS] System error
Measures: [TYPE_SRV] Servo OFF
Long:
Short:
EncoderError
EncoderErr
Main cause: An encoder and revolver signal problem was detected.
[Subcode]
1: No SIG0 signal edge
2: No SIG1 signal edge
3: SIG0 signal cycle problem
4: SIG1 signal cycle problem
Action to take: Contact us.