Parker Hannifin G2 Computer Drive User Manual


 
229 Excessive position deviation error processing type While in machine setting mode
Minimum value: 0
Maximum value: 5
Initial value: 1
Unit: None
Long:
Short:
OverSpeedErrorType
OVPeErrTyp
Specify the processing type when an excessive position deviation error occurs.
When operating the built-in controller axis:
0: Maintains the servo status after the axis operation stops (low level).
1: Turns the servo OFF after the axis operation stops (low level).
2: Stops the axis operation (low level) and turns the servo OFF immediately.
3: Maintains the servo status after the axis operation stops (high level).
4: Turns the servo OFF after the axis operation stops (high level).
5: Stops the axis operation (high level) and turns the servo OFF immediately.
When performing the higher controller follow-up:
0: Switches to the built-in controller, and maintains the servo status after a deceleration stop.
1: Switches to the built-in controller, and turns the servo OFF after a deceleration stop.
2: Switches to the built-in controller, performs a deceleration stop, and turns the servo OFF immediately.
3: Switches to the built-in controller, and maintains the servo status after an immediate stop.
4: Switches to the built-in controller, and turns the servo OFF after an immediate stop.
5: Switches to the built-in controller, performs an immediate stop, and turns the servo OFF immediately.