Parker Hannifin G2 Computer Drive User Manual


 
361 Velocity ratio gain
Unit: x 1/100
Displays the velocity loop ratio gain.
363 Velocity command value (digital)
Unit: 1/16 digit
Displays the velocity command value when controlling the digital velocity. (1msec sample)
364 Post-filter velocity command value (digital)
Unit: 1/16 digit
Displays the post-filter velocity command value when controlling the digital velocity. (1msec sample)
365 Present velocity current value
Unit: 1/16 digit
Displays the present velocity value. (1msec sample)
366 Present post-filter velocity value
Unit: 1/16 digit
Displays the present post-filter velocity value. (1msec sample)
367 Velocity deviation (digital)
Unit: 1/16 digit
Displays the velocity deviation. (1msec sample)
368 Current command value (D/A)
Unit: digit
Displays the current command value D/A output value. The conversion rate is as follows:
1 digit = 0.0036%
27853 digits: +100%
0 digits: 0%
-27853 digits: -100%
369 Present current value (A/D)
Unit: digit
Displays the A/D input value of the present current command value.(1msec sample) The conversion rate is as follows:
1 digit = 0.0036%
27840digits: +100%
0 digits: 0%
-27840 digits: -100%