9. MAJOR UNIT REPLACEMENT EO18-33027
9.13 RIBBON END SENSOR
9-27
9.13 RIBBON END SENSOR
1) Open the top cover. (Refer to Section 3.1.)
2) Turn the head lever to Free position and open the ribbon shaft holder plate.
3) Open the print head block.
4) Remove the E-ring from the left-hand ribbon guide shaft, as viewed from the head lever side, and
remove the ribbon guide shaft.
Ribbon Shaft
Holder Plate
Head
Leve
r
E-Ring
Ribbon Guide Shaft
Print Head Block
View from the lower front side
NOTE: Keep the removed Ribbon Guide
Shaft safe for future use.