Toshiba B-EX4 Printer User Manual


 
5. SYSTEM MODE EO18-33027
5.7 SENSOR ADJUSTMENT
5-56
5.7.3 Transmissive / TRANS.
It adjusts the sensor level of transmissive sensor.
Remove the label from the label paper and load the backing paper on the transmissive sensor and the
label should not be located on the sensor.
The display content of sensor level is updated each 200 msec.
The sensor level is adjusted by holding down [ENTER] key for 3 seconds.
When the adjustment is finished, “Adjustment complete” is displayed and asterisk (*) is marked at the
right side or voltage.
The range is below.
Transmissive sensor
0.0V 5.0 V
5.7.4 Paper empty level / PE REFL./TRANS.
It adjusts the paper empty level of reflective sensor and transmissive sensor.
Remove the paper located on the sensor.
The display content of sensor level is updated each 200 msec.
The sensor level is adjusted by holding down [ENTER] key for 3 seconds.
When the adjustment is finished, “Adjustment complete” is displayed and asterisk (*) is marked at the
right side or voltage.
The range is below.
Reflective sensor
0.0V 5.0 V
Transmissive sensor
0.0V 5.0 V
5.7.5 Ribbon end / RIBBON
It adjusts the ribbon end level.
Set the ribbon on the sensor.
The display content of sensor level is updated each 200 msec.
The sensor level is adjusted by holding down [ENTER] key for 3 seconds.
When the adjustment is finished, “Adjustment complete” is displayed and asterisk (*) is marked at the
right side or voltage.
The range is below.
Ribbon end sensor
0.0V 5.0 V