Toshiba B-EX4 Printer User Manual


 
5. SYSTEM MODE EO18-33027
5.3 SELF-DIAGNOSTIC TEST
5-6
Print condition:
Label length 490mm
Print method Setting by user
Sensor type Non
203dpi 6ips Speed
305dpi 5ips
Issuing number 1 piece
Issuing mode Setting by user
Other No mount winding motor
<< COUNTER >>
Item Content Range
Count condition
TOTAL FEED Total label distance covered (cannot be
cleared)
0.0 3200.0 km
Counts when the paper feed motor are driven to feed a paper or print. (Counts also during a reverse
feed operation.)
When the power is off, the label distance of 50.0 cm or less may be rounded down and backed up.
FEED Label distance covered
0.0 3200.0 km
Counts when the paper feed motor are driven to feed a paper or print. (Counts also during a reverse
feed operation.)
When the power is off, the label distance of 50.0 cm or less may be rounded down and backed up.
FEED1 FEED4
Label distance covered historical
0.0 3200.0 km
The label historical distance.
PRINT Print distance
0.0 200.0 km
Counts while printing. (Counting is not performed during reverse feed operation.)
B-EX4T1-G:
When the power is off, the print distance of 8.2 m or less is rounded down and backed up.
B-EX4T1-T:
When the power is off, the print distance of 5.5 m or less is rounded down and backed up.
PRINT1 PRINT4
Print distance historical
0.0 3200.0 km
The historical print distance.
CUT Cut count
0 1000000
Every cut operation is counted.
When the power is off, a cut count of 31 or less is rounded down and backed up.
HEAD U/D Head up/down count
0 2000000
Counts head up/down operations using the ribbon saving solenoid. (Combination of up and down
operations is counted as one.)
When the power is off, an up/down count of 31 or less is rounded down and backed up.
RIBBON Ribbon motor drive time
0 2000 Hour
Counts when the ribbon motor is driven to feed a paper or print. (Counts also during a reverse feed
operation.)
For B-EX4T1-G:
When the power is off, a drive time of 32 seconds or less is rounded down and backed up.
For B-EX4T1-T:
When the power is off, a drive time of 27 seconds or less is rounded down and backed up.
SOLENOID Head-up solenoid drive time
0 1000 Hour
Counts when the ribbon saving operation is performed.
For B-EX4T1-G:
When the power is off, a drive time of 32 seconds or less is rounded down and backed up.
For B-EX4T1-T: