4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO18-33027
4.10 UHF RFID KIT (B-EX700-RFID-U2-US/EU/CN-R)
4-59
3) Set an AGC threshold of data write.
Set a value which is lower than the AGC value by 1 or 2, taking variation of RFID tags in performance into
consideration.
(1) Choose “UHF SETTING”, and press the [ENTER] key.
(2) Choose “WRITE AGC THRESHOLD”, and press the [ENTER] key.
(3) Set a threshold value with [UP] or [DOWN] key, then press the [ENTER] key.
When the measured AGC was 9, for example, set “8” (a value lower than the measured AGC by 1
or 2.)
(4) Choose “WRITE RETRY MIN AGC”, and press the [ENTER] key.
(5) Set a lower limit with the [UP] or [DOWN] key.
Usually, set the same value with the AGC threshold for data write (WRITE AGC THRESHOLD).
In the case of this example, set “8” and press the [ENTER] key.
(6) AGC threshold setting is completed.