Toshiba B-EX4 Printer User Manual


 
5. SYSTEM MODE EO18-33027
5.5 PRINTER PARAMETER FINE ADJUSTMENT
5-46
5.5.9 Refrective sensor fine tune / THRESHOLD <REFL.>
Max. Min. Step Display Sign Integer
digit
Decimal
point
digit
0 fullfil Unit
4.0 0.0 0.1 Decimal Non 1 1 Non V
* If “0.0 V” is set, when the power is turned OFF then ON, the value “0.0 V” is returned to the initial value
(1.0 V).
5.5.10 Transmissive sensor fine tune / THRESHOLD <TRANS.>
Max. Min. Step Display Sign Integer
digit
Decimal
point
digit
0 fullfil Unit
4.0 0.0 0.1 Decimal Non 1 1 Non V
* If “0.0 V” is set, when the power is turned OFF then ON, the value “0.0 V” is returned to the initial value
(1.4 V).
Supplementary explanation
• When the [RESTART] and [FEED] keys are pressed at the same time, the display shows the
system mode menu.
• If the [RESTART] or [FEED] key is held down for 0.5 seconds or more when a fine adjustment
value is being set, the printer enters the repeat mode, in which the key is entered repeatedly.
• A changed fine adjustment value is stored in memory by pressing the [PAUSE] key.
• The printer is controlled by the sum of the fine adjustment parameter programmed on the
printer and the fine adjustment command from the PC. However, the maximum values for
each fine adjustment are as follows:
Feed fine adjustment .......................................................................±50.0 mm
Strip position fine adjustment........................................................... ±50.0 mm
Back feed fine adjustment ................................................................. ±9.9 mm
Print density fine adjustment.............................................................. ±10 step
X-coordinate fine adjustment........................................................... ±99.5 mm
Ribbon motor drive voltage fine adjustment (Rewind)............... -15 to +0 step
Ribbon motor drive voltage fine adjustment (Back tension) ......-15 to +0 step
• The X-coordinate fine adjustment is performed to finely adjust the X-coordinate of the drawing
in the left or right direction. Adjust the X-coordinate in the effective print range. (After the
value reaches the coordinate “0”, the value remains unchanged even if a subsequent fine
adjustment is performed in the negative direction.)
• The X-coordinate fine adjustment is not effective for the self-test results printout (maintenance
counter, various parameters, and automatic self-test) and the test print.
• The print density fine adjustment value is +0 step at the time of shipment from the factory.
The ribbon rewind/back tension motors drive voltage fine adjustment values are the sum of
the fine adjustment by the command (from the PC) and the fine adjustment in the system
mode (by key operation). The maximum fine adjustment values are -15 for both the ribbon
rewind motor and the ribbon back tension motor.
The print density fine adjustment value is the sum of the fine adjustment by command (from
the PC) and the fine adjustment in the system mode (by key operation). The respective max.