Toshiba B-EX4 Printer User Manual


 
5. SYSTEM MODE EO18-33027
5.11 RFID Module Setting
5-78
5.11.3.2 Issue retry label / ISSUE RETRY LABLES
This is a issue retry number after printing error pattern (void pattern) automatically when RFID write
error occur. Printer stop as RFID write error if RFID write does not success after retrying this number.
Max. Min. Step Display Sign Integer
digit
Decimal
point
digit
0 fullfil Unit
255 0 1 Decimal Non 3 0 Non Labels
5.11.3.3 Read retry / READ RETRY
It sets reading retry count and reading retry time.
The printer retries to read the data in the RFID tag for up to specified number of times. If the time-out
has come before the maximum number retries have been done, the printer stops the retries at the time.
Whenever the printer writes data onto the RFID tag, the tag is read first. The maximum number of
retries set by this parameter becomes also effective in this pre-read.
Max. Min. Step Display Sign Integer
digit
Decimal
point
digit
0 fullfil Unit
255 0 1 Decimal Non 3 0 Non times
Set the time-out for retry to read the RFID tag.
If the printer has retried for the maxim number of times within the RFID read retry time-out, the printer
stops the retries at the time.
Whenever the printer writes data onto the RFID tag, the tag is read first. The read retry time-out set by
this parameter becomes also effective in this pre-read.
Max. Min. Step Display Sign Integer
digit
Decimal
point
digit
0 fullfil Unit
9.9 0.0 0.1 Decimal Non 1 1 Non second