Toshiba B-EX4 Printer User Manual


 
4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO18-33027
4.10 UHF RFID KIT (B-EX700-RFID-U2-US/EU/CN-R)
4-58
4.10.5. AGC THRESHOLD SETTING
The B-EX700-RFID-U2-US/EU/CN-R chooses a tag to write data on according to a radio intensity of RFID tags
(AGC value).
An AGC threshold value has been set to 0 (00h) as factory default, but it may be necessary to change this value
according to the tag type to be used.
When the factory default threshold value is not proper for the tag type used, follow the procedure below to
configure the following settings.
As the changes are stored in the internal memory, they are retained after the printer power is turned off and on
again. When the tag type is changed or data write cannot be operated properly, perform the setting again.
Step 1. Load an RFID tag embedded media in the printer.
Step 2. Follow the procedure below to measure the radio intensity of the tags.
1) Place the media so that an RFID tag (IC chip) is positioned above the Antenna, and close the Top Cover.
Note: If an RFID tag is not positioned above the Antenna while the Print Head is at a print start position,
use @003 command to adjust the media position so that an RFID tag is positioned above the
Antenna. For detail of the command, refer to the External Equipment Interface Specification
(Printer Command Manual).
2 Start the printer in the system mode and perform a read test to measure the AGC value.
To measure the AGC value, place only one RFID tag on the Antenna.
(1) Turn the printer on while holding down the [MODE] key.
(2) Press the [DOWN] key until “<10>RFID” is highlighted.
(3) Press the [ENTER] key.
(4) Choose “UHF SETTING”, and press the [ENTER] key.
(5) Choose “Q VALUE”, and press the [ENTER] key.
(6) Set “2” with [UP] or [DOWN] key, then press the [ENTER] key.
(7) Turn off the printer.
(8) Turn the printer on while holding down the [MODE] key.
(9) Press the [DOWN] key until “<10>RFID” is highlighted.
(10) Press the [ENTER] key.
(11) Choose “TEST”, and press the [ENTER] key.
(12) Choose “ID READ”, and press the [ENTER] key.
(13) Press the [ENTER] key to read the tag data.
(14) Read data is displayed. Write down the AGC value.
(15) Press the [CANCEL] key to return to the <10>RFID.
Example
RFID Tag
ID READ
TAG 1/1
AGC 9
00010203 04050607
08090A0B 0C0D0E0F
(Example)