Toshiba B-EX4 Printer User Manual


 
5. SYSTEM MODE EO18-33027
5.3 SELF-DIAGNOSTIC TEST
5-15
AGC THRESHOLD RFID AGC threshold setting
0 15
WRITE AGC AGC threshold for data write
0 15
RETRY MIN AGC AGC threshold lower limit for
retry
0 15
OFF Detection is disabled.
ON(ID) RFID error tag
detection for ID area
data
TAG CHECK RFID error tag detection
ON ACCESS
PASSWORD
When PASS is selected,
the following settings are
subsequently displayed:
Password setting to
protect error tag
detection
ON: Enabled
OFF: Disabled
Automatic unlock
function setting
ON: Enabled
OFF: Disabled
ON Enable MULTI WRITE Hibiki tag multi-word write
OFF Disable
WRITE OK TAGS Count of RFID success label
write issue
0 9999999
VOID PRINT TAGS Count of RFID failure label
write issue
0 9999999
<< RTC >>
Item Content Print value
ON Enable BATTERY CHECK Battery check
OFF Disable
BATCH Each batch RENEWAL Time update timing
PAGE Each page