5. SYSTEM MODE EO18-33027
5.4 PARAMETER SETTING
5-32
Example of TYPE2
Case 1
Issuing number = 5, When label end is detected at 3
rd
label issuing.
(1) (2) (3)
↑
Stop by error after (3), LCD: “NO PAPER 2”
When printer is restarted, issue (4) (5) after initial feed.
The complete issued label is (1) (2) (3) (4) (5).
Case 2
Issuing number = 5, When label end is detected at 3
rd
label issuing. The remaining label length is longer
than 30 mm.
(1) (2) (3)
↑
Stop printing after 20mm printing as error, LCD: “NO RIBBON 2”
When printer is restarted, issue (4) (5) after initial feed.
The complete issued label is (1) (2) (4) (5).
Case 3
Issuing number = 5, When label end is detected at 3
rd
label issuing. The remaining label length is shorter
than 30 mm.
(1) (2) (3)
↑
Stop printing after issuing (3) as error, LCD: “NO RIBBON 2”
When printer is restarted, issue (4) (5) after initial feed.
The complete issued label is (1) (2) (3) (4) (5).
5.4.2.15 MaxiCode specification / MAXI CODE
TYPE1 Compatible with the current version
TYPE2 Special specification
The mode specified by the command may be different from the actual mode, depending on the status
of this parameter. Also, the data transmission method differs partly.
For details, refer to the External Equipment Interface Specification (EAA-03466).
5.4.2.16 XML
Disable / OFF Disable XML function
Standard / STD Standard specification
Oracle / ORACLE Specification for Oracle
SAP Specification for SAP
Standard external / STD EXT Standard specification (Use external memory)
Oracle external / ORACLE EXT Specification for Oracle (Use external memory)
SAP external / SAP EXT Specification for SAP (Use external memory)