Cisco Systems 15454M6DC Computer Accessories User Manual


 
5-47
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter 5 SONET Topologies
Linear ADM Configurations
Figure 5-37 A UPSR displayed in network view
Procedure: Convert a Linear ADM to a BLSR
The following procedures describe how to convert a three-node linear ADM to a BLSR. You will need
a SONET test set to monitor traffic while you perform these procedures.
Caution This procedure is service affecting.
Caution Always wear an authorized electrostatic discharge wrist band when removing or installing ONS
15454 cards.
Step 1 Start CTC and log into one of the nodes that you want to convert from linear to ring.
Step 2 Click the Maintenance > Protection tabs.
Step 3 Under Protection Groups, select the 1+1 protection group (that is, the group supporting the 1+1 span
cards).
Step 4 Under Selected Group, verify that the working slot/port is shown as Working/Active. If yes, go to Step
5. If the working slot says Working/Standby and the protect slot says Protect/Active, switch traffic
to the working slot:
a. Under Selected Group, select the protect slot, that is, the slot that says Protect/Active.
a. From the Switch Commands, select Manual.
b. Click Yes on the confirmation dialog box.