Cisco Systems 15454M6DC Computer Accessories User Manual


 
7-9
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter 7 Card Provisioning
Provisioning Electrical Cards
Note If the DS3E is installed in an ONS 15454 slot that is provisioned for a DS-3 card, the DS3E enhanced
performance monitoring parameters are not available. If this occurs, remove the DS3E from the ONS
15454, delete the DS-3 card in CTC, and provision the slot for the DS3E.
Procedure: Modify Line and Threshold Settings for the DS3E Card
Step 1 Display the DS3E-12 or DS3EN-12 in CTC card view.
Step 2 Click the Provisioning tab.
Step 3 Depending on the setting you need to modify, click the Line, Line Thrshld, Elect Path, or Sonet
Thrshld subtab.
Note See Chapter 10, Alarm Monitoring and Management for information about the Alarm
Behavior tab.
Step 4 Modify the settings shown in Table 7-4 on page 7-9. For drop-down lists, select an item from the list.
For numerics, double-click the field and type the new number.
Table 7-4 DS3E Card Parameters
Subtab Parameter Description Options
Line
Port # Port number 1 - 12
Port Port name To enter a name for the port, click the
cell and type the name. To change a
name, double-click the cell, then edit
the text.
Line Type Defines the line framing type
M23
C Bit
Auto Provisioned
Detected
Line Type
Displays the detected line type Read-only
Line
Coding
Defines the DS3E transmission
coding type
B3ZS
Line
Length
Defines the distance (in feet)
from backplane connection to
the next termination point
0 - 225 (default)
226 - 450
Status Places port in or out of service Out of Service (default)
In Service