Cisco Systems 15454M6DC Computer Accessories User Manual


 
7-12
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter 7 Card Provisioning
Provisioning Electrical Cards
Procedure: Modify Line and Threshold Settings for the DS3XM-6 Card
Step 1 Display the DS3XM-6 in CTC card view.
Step 2 Click the Provisioning tab.
Step 3 Depending on the setting you need to modify, click the Line, Line Thrshld, Elect Path, or Sonet
Thrshld subtab.
Note See Chapter 10, Alarm Monitoring and Management for information about the Alarm
Behavior tab.
Step 4 Modify the settings shown in Table 7-5. For drop-down lists, select an item from the list. For numerics,
double-click the field and type the new number.
Ta b l e 7- 5 D S 3X M - 6 Pa r am e t e rs
Subtab
Parameter Description Options
Line
Port # Port number 1 - 6
Port Port name To enter a name for the port, click the
cell and type the name. To change a
name, double-click the cell, then edit
the text.
Line Type Defines the line framing type
M23 - default
C BIT
Line Coding Defines the DS-1 transmission
coding type that is used
B3ZS
Line Length Defines the distance (in feet)
from backplane connection to
the next termination point
0 - 225 (default)
226 - 450
Status Places port in or out of service
Out of Service (default)
In Service
Line Thrshld
CV Coding violations Numeric. Defaults:
387 (15 minutes)
3865 (1 day)
ES Errored seconds Numeric. Defaults:
25 (15 minutes)
250 (1 day)
SES Severely errored seconds Numeric. Defaults:
4 (15 minutes)
40 (1 day)
Loss Loss of signal Numeric. Defaults:
10 (15 minutes)
10 (1 day)