7.2.4 DS3XM-6 Card Parameters
The DS3XM-6 transmux card can accept up to six DS-3 signals and convert each signal to 28 VT1.5s.
Conversely, the card can take 28 T-1s and multiplex them into a channeled C-bit or M23 framed DS-3.
Unlike the DS3-12 and DS3N-12 cards, the DS3XM-6 allows circuit mapping at the VT level. Table 7-5
on page 7-12 shows parameters that you can provision for each port.
Sonet
Thrshld
CV Coding violations Numeric. Defaults (Near End STS
termination):
15 (15 minutes)
125 (1 day)
ES Errored seconds Numeric. Defaults (Near End STS
termination):
12 (15 minutes)
100 (1 day)
FC Failure count Numeric. Defaults (Near End STS
termination):
10 (15 minutes)
10 (1 day)
SES Severely errored seconds Numeric. Defaults (Near End STS
termination):
3 (15 minutes)
7 (1 day)
UAS Unavailable seconds Numeric. Defaults (Near End STS
termination):
10 (15 minutes)
10 (1 day)
Alarming
Port Port number 1 - 12
Profile Sets the alarm profile for the
port.
Default
Inherited
Custom profiles (if any)
Suppress
Alarms
Suppresses alarm display for the
port.
Unselected (default)
Selected
Table 7-4 DS3E Card Parameters (continued)
Subtab Parameter Description Options